OCM OVERHEAT THERMOSTAT

OCM OVERHEAT THERMOSTAT

(1) 5 out of 5 stars
Model: PCT042-058

$28.97
Guaranteed Quality Pelton Crane OCM Autoclave Repair Parts

Part #PCT042-058
OEM Part #004108

OVERHEAT THERMOSTAT
  • Rated: Open between 220° F and 350° F; Factory set at 295˚ F.
  • Includes thermostat, and (2) terminal screw
Fits: Pelton Crane OCM Heating Element
Model This Part Fits: Pelton Crane OCM Autoclave

The Overheat Thermostat Is Located on The Heating Element (Or The Heating Element Bracket).

Tech Tip: Whenever changing heating elements, change the Overheat Thermostat at the same time.

How To Set The Pelton Crane OCM Overheat Thermostat


Although the Pelton Crane OCM Overheat Thermostat Is Pre-set at the factory, sometimes they need to be re-adjusted after you receive it. If this happens, proceed as follows:



  1. After installing the Overheat Thermostat, run a 15 amp AC ammeter in power supply line. As alternate, run a 120-volt voltmeter across the center heating element terminals.
  2. Starting from a cold condition, run a normal autoclaving cycle
  3. Remove temperature control knob on front of machine and rotate shaft to maximum position (turn clockwise)
  4. Current should be on when machine is at 270°F (27 PSI). If not, turn adjustment screw in overheat thermostat switch counter-clockwise to restore current. Safety valve should have released if pressure goes to 35 PSI


  5. CAUTION - DANGEROUS IF PRESSURE EXCEEDS 35 PSI


  6. At 270°F (27 PSI) turn screw clockwise until current is off (0 reading on meter used in #1 above). Then carefully turn screw counterclockwise until current starts up. Setting is now proper for switch if autoclave was started cold.
  7. The switch is now set and needs no further adjustment. Return to the temperature control shaft (#3 above), turning it counter-clockwise until it is set at 270°F (27 PSI). The knob can now be replaced.
  8. See the service manual for furthr adjusting instructions if needed
The Pelton Crane OCM Autoclave Repair Is Now Complete

"Pelton Crane OCM Autoclave Repair Made Simple™"
(1) 5 out of 5 stars
See all 1 reviews Write Review
100%

Dan Verified Buyer June 08, 2017 Illinois, United States
Thanks Wally for the quick diagnosis and phone help.. Will definetly recommend to anyone looking for the autoclave. I will go back to buy again. Thank you!!
Was this review helpful to you?YesNo
Share This Review

There is no any question about this product.

Qty

Fast Delivery
We usually ship the same day! All packages are shipped w/ Delivery Confirmation

100% Secure Payment
Your transaction is secure thanks to the paypal payment system: SSL (Secure Socket Layer)

Shopper Award

AllClaveParts Payment Methods