MAGNACLAVE HEATER STRIP (MAIN) 240V


$208.97

Add to Cart:


  • Description
  • Info & Guide
  • Specs
Part #PCH083-280
OEM Part #004502

MAIN HEATER STRIP (240V)
  • 1 KW, 240VAC, ~58ohms

Fits: Chamber
Model This Part Fits: Magnaclave

For Magnclave 240v Wall Heater Strip, Click Here

Learn How To Test The Magnaclave Heater Strip Lower On This Page

PCH083-280 MAGNACLAVE HEATER INSTALLATION INSTRUCTIONS

1. Remove old heater in normal fashion.
2. Inspect and clean outside of chamber.
3. Install new heaters, making sure that contact between heater and chamber is evenly distributed.

CAUTION: To assure no burnouts due to hot spots,
be certain that:

A. Chamber surface is dry and smooth.
B. Contact of heater to chamber is completely even and uniform.

4. Sequentially tighten tie down bands. The same amount of torque should be applied to all four bands (40 in. lbs.).
5. Perform final inspection. Verify that the curvature of the heaters matches the chamber and no gaps exist. Allow 10-15 minutes "burn-in" time.

Note: Excessive tightening of nuts may cause heater to fail.

Tech Tip: Be sure your original Pelton Crane Magnaclave Heating Element is defective before replacing it, by performing the following test

Testing The Pelton Crane Magnaclave Main Heater Strip

This test consists of measuring the amount of resistance in the element. To do this, first, turn the autoclave off and unplug it from the wall

WARNING: CURRENT MUST NOT BE PRESENT WHEN MEASURING RESISTANCE.

Set your volt/ohm meter on 200 ohms (200 NOT 200k). The ohms range is located within the Omega (Ω )(look for this symbol) section of your meter. It is also the area with "k" ranges (ie: 2000k,. 200k, 20K and then 2000, 200).

Place a probe from the volt/ohm meter on each wire where it connects to the element (it really doesn't matter which color probe goes where).

For the heating element to be good, it must fall within the resistance range in this table (between 52.2 and 63.8 ohms) If your reading is outside of this range, then it is defective and needs to be replaced.
Model Volts Watts Amps Resistance Resistance Range
Magnaclave Main Heater Strip
240vac 1000 4.1667amps ~58 Ohms 52.2 63.8 ohms





Customer Reviews
Solution Graphics
Pay By Credit Or Debt Card
-Pay By Credit Card-
Proceed To Checkout And Enter Your Credit Card Information In Step 2

Pay By Credit Or Debit Card
To Order By Phone Call
636-390-2792
Mon thru Fri 8:00am To 4:30 pm Central Time

Testimonials

Don't Take Our Word For It.....


Customer Reviews


AllClaveParts.com - Real Help With Your Autoclave Repair When You Need It

"My Statim 2000 stopped working.

Benco dental came down and said the thermal fuse and computer board was bad

Real Problems Solved By Dr Gorenburg With AllClaveParts help

Wally, thank you and your company for providing great customer service and all the help I needed to fix my autoclave.
Clearview Medical.com

Dr Haruki & Son

My tech told me my STATIM 2000 repair could either be about $350 (if it was only the thermal fuse) or up to $1500 if it was another problem.

Craig Haruki DDS
Lihue, HI


Dr Whitehouse Loves AllClaveParts.com
"It was a pleasure working with Wally who saved me thousands over what I would have had to pay when the Patterson tech......"

Dr Joseph Whitehouse
Castro Valley, CA
Create A Smile


Dr Steve Says Midmark Told Him To Throw It Away, But AllClaveParts Showed Him How To Fix It Well, that same autoclave is once again working like a champ thanks to allclaveparts.com.

Steve Douglas, DDS
Indianapolis, IN
stevedouglasddspc.com


Parse Time: 0.296 - Number of Queries: 227 - Query Time: 0.119043166367
Content

Check Out Our Specials


A Best Seller
Click Here To Check Out Everything On Sale